Keithley DAQ6510 | Modular data acquisition and logging system, multimeter system, 2 slots, integrated 6½-digit digital multimeter, connection of up to 80 test objects.
Manufacturer number: DAQ6510
Keithley DAQ6510 | Modular data acquisition and logging system, multimeter system, 2 slots, integrated 6½-digit digital multimeter, connection of up to 80 test objects.
- 2 module slots, diverse selection from 12 plug-in modules for connecting up to 80 test objects
- Integrated 6½-digit digital multimeter (DMM): basic accuracy 0.0025% (1 to 10 V)
- Front panel sockets for stand-alone operation of the DMM
- Scanning speed: up to 800 channels / s (with solid-state relay module)
- Voltage measurement: 100 nV to 1010 V (DC), 100 nV to 750 VRMS (AC)
- Current measurement: 10 pA to 3 A (DC), 100 pA to 3 A (AC)
- Frequency measurement: 3 Hz to 300 kHz
- Temperature measurement: -200 to +1820 ° C (thermocouple), -80 to 150 ° C (thermistor), -200 to 850 ° C (RTD)
- Resistance measurement: 10 µΩ to 120 MΩ (two-wire), 1 µΩ to 120 MΩ (four-wire)
- 15 measurement functions
- Maximum power consumption: 65 VA
- Internal memory for max. 7 million measurements
- 12.7 cm (5 inch) capacitive TFT touchscreen with graphic display
- Interfaces: USB 2.0 (devices), USB 2.0 (host), LAN / LXI, optional: GPIB, RS-232, TSP-Link
- Power supply: 100/240 V AC, 50/60 and 400 Hz
- Dimensions: W 224 x H 10.2 x D 387.4 mm (tabletop unit) / W 213.8 x H 8.4 x D 356.6 mm (rack mounting)
- Transport weight: 4.5 kg
- Warranty: 3 years
Technical Data
2-/4-wire: | 2-/4 |
---|---|
Accuracy voltage measurement AC: | 0,04 % |
Accuracy voltage measurement DC: | 0,0030 % |
Article number: | DAQ6510 |
Available modules: | 7700: 20-Kanal Differential-Multiplexer, bis 50 MHz Bandbreite, Auto-CJC (Cold Junction Compensation), mit Schraubklemmen 7701: 32-Kanal Differential-Multiplexer, 25- und 50-Pin D-Sub-Anschluss (female) 7702: 40-Kanal Differential-Multiplexer, mit Schraub |
Current measuring range AC: | 100 µA - 3 A |
Current measuring range DC: | 10 µA - 3 A |
Dimensions (L x W x H) (mm): | 387,4 x 224 x 107,2 |
Diode test / continuity test: | Yes / Yes |
Display: | 5" TFT touchscreen display |
Frequency measuring range: | 3 Hz - 300 kHz |
Interfaces: | GPIB, RS-232, Digital I/O, TSP Link |
Measured value memory: | Buffer: 7 Ms/s |
Model: | DAQ6510 |
Number of DMM positions: | 6.5 |
Number of channels: | 400 |
Number of plug-in modules: | 3 |
Number of positions: | 6.5 |
Resistance measuring range: | 1 Ω - 100 MΩ |
Special features: | 2-module slots for up to 12 different modules |
Temperature measurement: | Yes |
Temperature measuring range: | -200 °C - 1820 °C |
Voltage measuring range AC: | 100 mV - 750 V |
Voltage measuring range DC: | 100 nV - 1010 V |
Warranty (years): | 3 |
Weight (kg): | 4.54 |
max. Measuring range DC (V): | 1000 |
min. Measuring range DC (mV): | 100 |
Documents & Downloads
Description
DAQ6510 | Modular data acquisition and logging system, multimeter system, 2 slots, integrated 6½-digit digital multimeter, connection of up to 80 test objects.
The DAQ6510 is a fully equipped 6½-digit digital multimeter (DMM) for high-performance measurements on electronic components and devices. The 12 available plug-in modules offer you a high degree of flexibility for setting up a wide variety of data acquisition or test systems. To maximize the measurement speed, measurements up to 0.0005 power line cycles (PLC) or 8.3 μs for 60 Hz power lines (10 μs for 50 Hz power lines) can be performed. When analyzing transient signals, use the DAQ6510's digitize function to capture a voltage or current waveform at up to 1 MSa / s.
The DAQ6510 has input sockets on the front control panel, which enable it to be used as a 6½-digit DMM for tests and troubleshooting. If no multi-channel measurements are required, the DAQ6510 acts as a data logger. This double functionality enables maximum utilization of your device.
Variety of applications thanks to plug-in cards:
With the 12 available switching and control modules, a test system can be set up that measures or controls up to 80 test objects (DUTs) in a multiplex configuration. The DAQ6510 is equipped with two 6 x 8 matrix modules, for a total of 96 crosspoints, and can therefore test one or more ICs. To carry out production tests in large quantities, select the semiconductor relay module to optimize throughput with a scanning speed of up to 800 channels per second. Additional modules have cold junction compensation as well as temperature references for temperature monitoring of the thermocouples during environmental tests and accelerated life tests with HALT (Highly Accelerated Life Test) and HASS (Highly Accelerated Stress Screen).
Overview of plug-in modules:
- 7700: 20-channel differential multiplexer, up to 50 MHz bandwidth, Auto-CJC (Cold Junction Compensation), with screw terminals
- 7701: 32-channel differential multiplexer, 25- and 50-pin D-Sub connector (female)
- 7702: 40-channel differential multiplexer, with screw terminals
- 7703: 32-channel high-speed differential multiplexer, 2x 50-pin D-Sub (female)
- 7705: 40-channel control module, single-pole, 2x 50-pin D-Sub (female)
- 7706: All-in-one I / O module: 20-channel differential multiplexer, auto-CJC, 16 digital outputs, 2 analog outputs, use as a counter, with screw terminals
- 7707: digital I / O module, 32-channel, with 10-channel differential multiplexer, 50-pin D-Sub (male)
- 7708: 40-channel differential multiplexer, Auto-CJC, with screw terminals
- 7709: 6 x 8 matrix switch module, 25- and 50-pin D-Sub (female)
- 7710: 20-channel solid state multiplexer (semiconductor differential multiplexer), Auto-CJC, with screw terminals
- 7711: Dual 1 x 4 RF module, 50 Ω, 2 GHz bandwidth, SMA connections
- 7712: Dual 1 x 4 RF module, 50 Ω, 3.5 GHz bandwidth, SMA connections
Automated test systems:
The DAQ6510 has built-in intelligence to run a test script, make decisions, and control other instruments. Using the Keithley Test Script Processor (TSP) measurement and control language, the user can either run existing scripts or write their own scripts. With TSP scripting, complete test programs in the form of test scripts can run directly on the device. Use a TSP script and the TSP link interface to carry out a test for communication from device to device without any external PC control.
Software for simplified PC control, data acquisition and analysis:
KickStart allows you to configure, test and collect data for multiple devices such as DMM, data loggers, power sources and SMU. You can control up to eight devices simultaneously and view millions of readings per device. For the best overview, KickStart displays your data graphically and also offers comparison functions for data from the history. Use KickStart to set up, program and control the DAQ6510, to configure channels, set limit values or trigger sources and read the results in real time within a few minutes. The native drivers for Labview, IVI-C and IVI-COM are also available for download for the personal application software of your choice.
Lieferumfang
- 1757 standard test lead set, 1 pair, 1000 V Cat ll
- USB-B-1 USB cable, type A to B, 1 m