Pico TA042 | Probe, differential 100X / 1000X, 100MHz, 1400V, BNC
Manufacturer number: TA042
or choose one of the following options:
Pico TA042 probe, active, differential 100X / 1000X, 100MHz, 1400V
Documents & Downloads
Description
TA042 | Probe, differential 100X / 1000X, 100MHz, 1400V, BNC
Specifications for the TA042 differential probe:
- Bandwidth: DC to 100 MHz (- 3 dB)
- Input impedance: 4 MΩ / 7 pF from each input to ground
- Attenuator: 100: 1 switchable to 1000: 1
- Input voltage: - Max. Differential voltage with attenuation 1/100: ± 140 V (DC + peak AC) or 140 V rms- Max. Differential voltage with attenuation 1/1000: ± 1400 V (DC + peak AC) or 1000 V rms - Common mode input voltage: ± 1400V (DC + peak AC) or 1000 V rms (with attenuation 1/100 and 1/1000)
- Maximum input voltage: - Differential or in common mode: ± 1400 V (DC + peak AC) or 1000 V rms CAT III (with 1/100 and 1/1000 attenuation)
- Accuracy: ± 2%
- Rise time: 3.5 ns
- Output voltage: - Signal (in 50 kΩ load): ± 7V- offset (typical): <± 5 mV- noise (typical): 0.9 mV rms- source impedance (typical): 50 Ω
- Supply voltage: 4 x AA batteries or 6 V / 200 mA, via DC adapter 9 V / 120 mA
- Length of the connecting wires: 30 cm
- Length of the shielded BNC cable: 90 cm
- Weight: 500 g
- Dimensions: W 83 x L 207 x H 38 mm
About the Manufacturer
Pico
Pico Technology, the leader in USB oscilloscope technology, offers
innovative, high-quality and affordable alternatives to traditional
benchtop meters. The wide range of PC-based digital oscilloscopes offers
a full range of functions. The Pico data loggers are ideal for
measuring and storing temperature, humidity, current and voltage.