With its outstanding functions, the CNT-91 frequency analyzer from Pendulum Instruments occupies a special position on the market. It enables continuous data transmission during the measurement process and can therefore shorten your test times. Frequency and time domain measurements are carried out without dead time, so that you can also record very fast signal changes or random events. The outstanding graphic display contributes to the optimal interpretation of your measurement results by displaying the measured values both numerically and in the form of histograms, trend lines, etc. You receive all the essential signal information without the need for additional measuring devices such as a multimeter. The parameter setting is menu-oriented, which enables particularly controlled and simple device operation. Visual instructions support you during calibration.
The powerful CNT-91 frequency counter is also characterized by its high measurement speed and resolution. It enables up to 250,000 measurements per second. The measurement resolution for the time domain measurement is up to 50 ps. The CNT-91 displays frequency measurements with up to 12 digits. This makes it a universal high-performance counter and timer for use in research, development and production, particularly in automated test systems to determine the attenuation or phase shift of a filter, for example.
With the Modulation Domain Analyzer software TimeView 3, you can expand the measurement and statistics functions of your CNT-91. Thanks to the high measurement speed, very rapid signal changes in time or frequency can be analyzed in real time, e.g. B. Hopping frequencies up to 20 GHz, CW (continuous wave), Doppler pulse or chirp radar signals, digital modulations or even frequency stability (Allan deviation ADEV).
High Performance Timer / Counter / Analyzer:
- Continuous data transmission via GPIB/USB at the same time as the measurement process for a high test throughput (up to 4,000 Sa/s)
- Zero dead time technology enables the correct determination of the Allan deviation (ADEV)
- High resolution with 50 ps for time and 12 digits for frequency measurements enables the detection of very small frequency changes (display of up to 14 digits), for efficient use in research, development and production
- Programmable output frequency for signals with a fast rise time from 0.5 Hz to 50 MHz, for use as a reference output, trigger source or universal signal source
- Very high accuracy thanks to OCXO time reference for calibration purposes
- Large frequency range up to 20 GHz for all CW (continuous wave) and burst HF applications up to 40 ns
- Clear display for optimal interpretation of your measurement results with histogram, trend line, numerical statistics, modulation domain
Please note: Special items may show signs of use. Special items have a 1 year guarantee. The item is subject to prior sale. The configuration of a special item cannot be changed.
Give us a call, we will be happy to advise you personally:
+49 (0)7121 / 51 50 50