#statusMessage#
Do you want to start the compare now?
#statusMessage#
Do you want to start the compare now?
With the increasing importance of renewable energies in the wake of climate change, solar energy is moving further into ...
The complexity of military radios and the often harsh weather conditions have a negative impact on the reliability of ra...
Automation with thermal imaging technology has proven to be a reliable solution for quality control in various industrie...
In diesem exklusiven Whitepaper erfahren Sie, wie Sie mit der richtigen Messtechnik arbeiten: ✔ Sie realisieren ein Test...
Manufacturer number: CNT-91R
AC input: | 100 VAC - 240 VAC, 50 Hz - 400 Hz (Nom.), < 50 W |
---|---|
Article number: | CNT-91R |
Dimensions (L x W x H) (mm): | 395 x 210 x 90 |
Event Count (Totalize): | 250.000 |
Input impedance: | 1 MΩ parallel 20 pF or 50 Ω |
Interfaces: | USB, LAN |
Measurement functions: | Frequency, period, time range, phase, duty cycle, pulse duration, rise-fall time |
Measurement resolution (gate time): | 1,6 ns |
Measuring range RF (MHz): | 400 |
Measuring resolution: | 12 digits/s |
Messwertstatistik: | current measured value, minimum, maximum, standard deviation |
Min. pulse width: | 50 ps |
Model: | CNT-91R Rubidium-Zeitreferenz |
Number of channels: | 2 |
Options/Extensions: | Optional: Kanal 3 (3 GHz, 8 GHz, 15 GHz, 20 GHz) |
Sensitivity: | 15 mVrms: 200 MHz / 25 mVrms: 200 MHz - 300 MHz / 35 mVrms: 300 MHz - 400 MHz |
Trigger source: | Intern, Extern, Bus, Manuel |
Warranty (years): | 3 |
Weakening: | Trigger Range: x10 / x1 |
Weight (kg): | 2.7 |
With its outstanding functions, the frequency analyzer CNT-91R from Pendulum Instruments occupies a special position on the market. It enables continuous data transmission even during the measurement process and can thus shorten your test times. Frequency and time domain measurements are carried out without dead time, so that you can also record very fast signal changes or random events. The outstanding graphic display contributes to the optimal interpretation of your measurement results by displaying the measurement values both numerically and in the form of histograms, trend lines, etc. You receive all essential signal information without additional measuring devices such as B. a multimeter is required. The parameter setting is menu-oriented, which enables particularly controlled and simple device operation. Visual instructions will help you with the calibration.
The powerful frequency analyzer CNT-91R is also characterized by its high measuring speed and resolution. It enables up to 250,000 measurements per second. The measurement resolution for the time domain measurement is up to 50 ps. The CNT-91R displays frequency measurements with up to 12 digits. The CNT-91R's time reference is based on an integrated, highly stable rubidium oscillator. The frequency analyzer is used both as a universal high-performance counter and timer in automated test systems and as a calibrator for frequency sources.
The TimeView 3 modulation domain analyzer software extends the measurement and statistical functions of your CNT-91R. Thanks to the high measuring speed, very fast signal changes of time or frequency can be analyzed in real time, e.g. B. hopping frequencies up to 20 GHz, CW (continuous wave), Doppler pulse or chirp radar signals, digital modulations or frequency stability (Allan deviation ADEV).
High Performance Analyzer / Calibrator / Timer / Counter: