Manufacturer number: CNT-90XL-60G
AC input: | 100 VAC - 240 VAC, 50 Hz - 400 Hz (Nom.), < 50 W |
---|---|
Article number: | CNT-90XL-60G |
Dimensions (L x W x H) (mm): | 395 x 210 x 90 |
Event Count (Totalize): | 250.000 |
Input impedance: | 1 MΩ parallel 20 pF or 50 Ω |
Interfaces: | USB, LAN |
Measurement functions: | Frequency, period, time range, phase, duty cycle, pulse duration, rise-fall time |
Measurement resolution (gate time): | 1,6 ns |
Measuring range HF (or MikroW) (GHz): | 60 |
Measuring range RF (MHz): | 400 |
Measuring resolution: | 12 digits/s |
Messwertstatistik: | current measured value, minimum, maximum, standard deviation |
Min. pulse width: | 100 ps |
Model: | CNT-91R Rubidium-Zeitreferenz mit Input C 60GHz |
Number of channels: | 3 |
Sensitivity: | 15 mVrms: 200 MHz / 25 mVrms: 200 MHz - 300 MHz / 35 mVrms: 300 MHz - 400 MHz |
Trigger source: | Intern, Extern, Bus, Manuel |
Warranty (years): | 3 |
Weakening: | Trigger Range: x10 / x1 |
Weight (kg): | 2.7 |
The multifunctional frequency counter CNT-90XL from Pendulum Instruments is used on the one hand as an ultra-fast and high-resolution 400 MHz universal counter and timer. As a high-performance analyzer for the precise measurement and calibration of frequencies, powers and pulsed HF up to 30 ns, e.g. B. the pulse width or PRI / PRF (pulse repetition interval / frequency), it is also used in research and development, in radar tests or in calibration laboratories. Its speed enables up to 250,000 measurements per second. The measurement resolution for the time domain measurement is up to 100 ps. The CNT-90XL displays frequency measurements with 12 digits. The unique user-friendliness of the CNT-90XL with graphic and numerical display enables optimal control over your analyzes. The portable frequency counter with battery is available for maximum versatility.
High performance timer / counter / analyzer:With the modulation domain analyzer software TimeView 2, you can expand your measurement and statistical functions to analyze dynamic signal changes of time or frequency in real time, e.g. B. for measuring frequency stability (Allan deviation, ADEV) or for FFT to find modulation frequencies.
Examples of use: