Keysight 34933A | 4 x 8 reed matrix for data logger 34980A
Manufacturer number: 34933A
On Request
Keysight 34933A | Dual / Quad 4x8 relay matrix plug-in module for modular measurement data acquisition / switching system 34980A.
- Two 4x8, 8x8, or 4x16 2-wire configurations are possible
- 64 2-wire or 128 1-wire as a cross-point version
- High speed reed relay
- Connection to the internal digital multimeter
- Expandable with four 2-wire analog bus lines
- Relay counter
- Switching capacity ± 150V peak voltage, 1.5A continuous current; 0.5A switching current
- Module connection: 2 - 50-pin Dsub, male
- Warranty: 3 years
Documents & Downloads
Description
34933A | 4 x 8 reed matrix for data logger 34980A
The 34933A module is a slot for the Keysight (formerly Agilent's electronic measurement technology) 34980A measurement data acquisition system and, with the 4x8 relay matrix, offers a universally usable and very densely packed unit for simultaneously using different measurement instruments at different test points of a module to be tested (DUT / Device Under Test).
Several matrix modules can be controlled via the analog bus of the 34980A in order to be able to set up a measuring system with an even higher number of channels. 1024 channels can be realized with 2-wire measurements - and this with a basic device.
This module can be configured as a single wire matrix to increase the number of channels. Several matrix modules can be controlled via the analog bus of the 34980A in order to be able to set up a measuring system with an even higher number of channels. 1024 channels can be implemented as 1-wire measurements - and this with a basic device.
This module can also be configured for 1 or 2-wire measurement. The optional connector blocks and the very tightly packed screw contact strips offer enough space for the cables and establish a robust connection to the DUT (Device Under Test).
The standard 78-pin Dsub connector can be used to contact normal cables and terminal strips.