HT 2002225 | Smart-Test HT700 test device according to VDE 0701-0702 DGUV regulation 3
Manufacturer number: 2002225
On Request
HT SMART TEST HT700 | Test device for safety-related checking of AC consumers and extensions according to DIN VDE 0701-0702 / DGUV regulation 3.
- Test according to DGUV regulation 3, DIN VDE 0701-0702
- Voltage measurement SELV / PELV via probe: 0.0 V… 440.0 V AC / DC
- Current measurement IL1 (optional current clamp): 0.00 A… 16.00 A (0.00 A… 40.00 A)
- Power measurement: 0 W… 4,000 W || Standby || 0.000 W… 9.999 W (current max. 50 mA)
- Test sequences: SKI active, SKII active, extension, permanent connection, SKI with pliers, individual measurements
- Protective conductor resistance: 0.000… 4.000 || Test current 200 mA DC / open circuit voltage 10 V
- Insulation resistance: 0.00 M… 20.00 M || Open circuit voltages 250 V, 500 V || Short-circuit current 1 mA
- Integrated residual current switch-off: residual current> approx. 20 mA
- Differential current according to DIN EN 61557-14 for the correct evaluation of the harmonics: 0.00 mA… 20.00 mA AC || optional current clamp 0.00 mA… 40.00 mA
- Touch current: 0.000 mA… 4.000 mA
- Mains voltage measurement: 200 V… 250 V AC
- Automatic limit value setting (protective conductor, insulation)
- Measurement of extension cables and devices with protective extra-low voltage
- Testing of permanently connected devices possible
- Two-pole measurement (low resistance, insulation, substitute leakage current, voltage)
- Checking the mains connection for PE connection and automatic shutdown in the event of a dangerous fault current of the device under test
- Standby measurement and lightning-fast polarity reversal
- Leakage current and consumer current measurement with optional current clamp
- Interface: Bluetooth
- Mains connection: AC 230 V ± 10%, operating ambient temperature: 5 ° C… 40 ° C
- DIN EN 61557-16 / EN 61010
- DIN EN 61326
- CAT II 300 V
- IP 20, closed waterproof IP 67
- Dimensions: 259 mm x 251 mm x 114 mm
- Weight: approx. 1 kg
Technical Data
Article number: | 2002225 |
---|---|
Automatic test sequence: | Yes |
DIN VDE0544-4 / IEC 60974-4: | No |
DIN VDE 0701-0702: | Yes |
DIN VDE 0751 / IEC62353: | No |
Differential power: | 0,03 mA bis 20 mA |
Dimensions (L x W x H) (mm): | 259 x 251 x 114 |
EN 50678 (prepared): | No |
EN 50699 (prepared): | No |
Earth conductor 10A: | No |
Earth conductor 25A: | No |
High voltage test DC: | No |
Interfaces: | Bluetooth, USB |
Isolation: | 0,00 MΩ bis 20,00 MΩ |
Measured value memory: | Datenbank des Smartphones |
Mobile: | Yes |
Model: | Smart-Test HT700 |
Protective earth less than 200mA: | Yes |
Software included: | Smartphone APP |
Stationary: | No |
Touch Display: | Yes |
Weight (kg): | 1 |
Description
2002225 | Smart-Test HT700 test device according to VDE 0701-0702 DGUV regulation 3
The handy test device Smart-Test HT700 is used for testing after repairs and for retesting electrical work equipment with a connected load of up to 4 kW, extensions, permanently connected test specimens and via adapters for testing three-phase consumers.
The test sequences are carried out via an Android app on the smartphone (included in the scope of delivery), coupled with the test device via a Bluetooth connection. The test sequence is menu-driven with simple, graphic profile selection and animated images to illustrate the measuring principle. At the same time as the test, photos of the master data or the test can be taken by the smartphone camera. Barcodes for the identification of the test objects are also scanned by the smartphone camera or by a separate barcode reader, which is coupled via Bluetooth. In order to meet different user groups, the user profiles "Expert" and "Standard" can be set.
The measured values are automatically saved in a database, a PDF report with a preselectable company logo is created automatically at the end of a test procedure.
The special features of the Smart-Test HT700 are the standby power measurement according to EU regulation 1275/2008 and a lightning-fast polarity reversal.
Product features:
- Test according to DGUV regulation 3, DIN VDE 0701-0702
- "Ready-to-use" The smartphone included in the scope of delivery has already installed the APP application and the APP barcode application and is thus prepared for direct use
- Operation via Android app Test-Master with SQLITE3 database, PDF protocol creation with company logo and signature
- Photo documentation, smartphone barcode reading function
- Automatic limit value setting (protective conductor, insulation)
- Measurement of extension cables and devices with protective extra-low voltage
- Testing of permanently connected devices possible
- Two-pole measurement (low resistance, insulation, substitute leakage current, voltage)
- Checking the mains connection for PE connection and automatic shutdown in the event of a dangerous fault current of the device under test
- Fast running of all active tests including function test with real-effective performance display in just one step
- Standby measurement and lightning-fast polarity reversal
- Leakage current and consumer current measurement with optional current clamp
Lieferumfang
- Tester
- Smartphone Xiaomi Redmi 7A
- Red / black test leads, 2 m
- Factory calibration certificate
- Schuko connection cable
- Bag for accessories
Accessoires (24 products )
Recommendations (7 products )
News and Knowledge
The DIN VDE regulations govern the electrotechnical regulations as defined by DGUV V3 (accident prevention regulations f...
Thomas Schleich is an engineer, an expounder of ideas, a free spirit – and a first-class speaker at the dataTec Academy....