GW Instek LCR-6002 | LCR meter, 10 Hz to 2 kHz
Manufacturer number: LCR-6002
GW Instek LCR-6002 / LCR meter, 10 Hz - 2 kHz, RS232, USB, handler interface.
- Test frequency range:10Hz to 2 kHz (accuracy: ± 0.01%, resolution: 4 digits)
- Test frequency is continuous over the entire frequency range or a frequency point
- 10 application-specific test parameter sets can be saved and called up continuously
- Basic accuracy: 0.05%
- Maximum measurement speed: 25ms
- Combination of 16 main and secondary parameter measurements and additional monitoring of two parameters. A maximum of 4 different parameters can be shown simultaneously on the display
- DC resistance measurement and internal DC voltage source with ± 2.5 V
- PASS/FAIL decisions
- Automatic Level Control (ALC)
- BIN function offers 9BIN and 1AUX, 10 BIN in total, corresponds to component sorting into 10 classes
- 10 levels for test sequences, whereby 10 test parameter sets such as frequency, voltage and current can be set and saved.
- Color LCD display: 8.9 cm diagonal, (3.5 inch)
- Standard interface: RS-232C, USB memory/device and handler interface
- Mains power supply: AC 90V-250V, 50-60Hz, max. input power: 30 VA
- Compact design, ideal for automated test systems, height: 2U, width: 1/2 rack width
- Dimensions: Width: 265 mm x Height: 107mm x Depth: 312 mm,
- Weight: 3kg
- Warranty: 1 year
Technical Data
Accuracy: | 0,05 % |
---|---|
Article number: | 01CR600200GT |
Compensation functions: | Yes |
DC Bias: | internal: 2V / external with adapter: 40 V |
Dimensions (L x W x H) (mm): | 312 x 265 x 107 |
Displayable measurement parameters: | Cp, Cs, Lp, Ls, Rs, Rp |
Handlerinterface: | Yes |
Interfaces: | USB, RS-232 |
Listsweep: | Yes |
Measurement functions: | Z, L, C, R, DCR, LCZ |
Model: | LCR-6002 |
Resolution: | 4-Digits |
Special features: | graphical representation with software |
Testadapter: | Yes (Axial, Radial, SMD) |
Testlimits: | Yes |
Warranty (years): | 1 |
Weight (kg): | 3 |
max. Frequency range (MHz): | 0.002 |
min. Frequency range (Hz): | 10 |
Documents & Downloads
Description
LCR-6002 | LCR meter, 10 Hz to 2 kHz
The series of LCR-6000 measuring devices is very compact and offers a rich portfolio of measuring functions. A 3.5-inch color LCD display ensures reliable reading of the measured values and the set parameters. Two measured values and two setting parameters can be displayed simultaneously. This simplifies the measurements and leads to faster classification of the measured values, especially when electronic components such as B. capacitors in sorting processes must be divided into different tolerance categories. A PASS / FAIL display is also helpful here, whereby the tolerance limits can be freely set.
Two zero-adjustment methods that cover the entire frequency range or specifically one measurement frequency are convenient for measurements. Users who change the connected test adapter without switching off the device can change the frequency within the frequency range and carry out measurements. The repetitive "zero adjustment" can save considerable time. In addition, the frequency ranges can be called up continuously, which allows the user to set precise measurement frequency values with which the component measurements are carried out.
This series offers further possibilities for material tests such as: B. Automatic level control (ALC) to stabilize the test voltage when measuring ceramic multilayer capacitors (Multi-Layer Ceramic Capacitor / MLCC) or when measuring inductances by using the individually adjustable test current value to determine the DC Resistance of the winding body can be fixed. An integrated ± 2.5 V bias voltage source is available for material testing. Optional adapters that provide either ± 45 V or ± 2.5 A can be connected to the device. To determine trends in DUTs (Device under Test), measurement parameters can be saved in 10 levels, which offers the user the option of different parameter value sets for e.g. B. to set frequency, voltage and current.
Up to 10,000 measured values can be stored in the measured value memory for repetitive measurements that can be read out via the USB interface on an external memory (USB stick) without having to connect a PC. Likewise, the respective display values and setting parameters can be transferred to the external memory via the USB interface.
For automated tests in production, the LCR-6000 series is equipped as standard with a handler interface, via which 9BIN, AUX: 1BIN can be used to select the tested components. Overall, the measured components can be assigned to 10 tolerance classes (10BIN). The device is programmable via the integrated RS232 and USB interfaces and the measured values can also be read out. A freely available software enables the user to automatically save the measured values, which saves program development time.
This LCR6000 device series is used in the development, production, quality control and sorting of manufactured components.
Lieferumfang
- safety instructions
- Power cord
- LCR-06A Kelvin test clips
- CD with operating instructions and PC software
Optional accessories:
- LCR-05, test adapter for axial and radial component designs
- LCR-06A, Kelvin test clips
- LCR-07, test adapter, with alligator clips, 2-wire
- LCR-08, tweezers test adapter for SMD / chip components
- LCR-15, test adapter for SMD / chip components (0603 to 4532 (metric code), corresponds to: 0201 to 1812 (imperial code))
- LCR-16, test adapter for ± 45V DC bias voltage
- LCR-17, test adapter for ± 2.5A DC bias current
- GTL-232, RS-232C cable, 9-pin socket, approx. 2 m
About the Manufacturer
Good Will has been listed on the Taiwan Stock Exchange since 2000. Development and production focus on high quality and low cost measuring instruments for production, laboratory and education. Headquartered in Taipei, Good Will has subsidiaries in China, America, Japan, Korea and Malaysia. The products are sold in over 80 countries.