Gossen Metrawatt M712U | Minitest MASTER device tester VDE 0701-0702 test device, LCD display, memory
Manufacturer number: M712U
Test device MINITEST MASTER from Gossen Metrawatt for DIN VDE 0701-0702 with data memory.
- Limit violations are indicated by LEDs
- Probe line protected by fuse
- Digital display for measured values
- USB interface for data logging
- RCCB installed
- Comprehensive security facilities
- Memory for 2000 tests with 10 measured values each
- RS232 interface for RFID or barcode readers
- incl. MINITEST MASTER software for reading and printing the measured values
Technical Data
Article number: | M712U |
---|---|
Automatic test sequence: | No |
DIN VDE0544-4 / IEC 60974-4: | No |
DIN VDE 0701-0702: | Yes |
DIN VDE 0751 / IEC62353: | No |
Differential power: | 0,1 - 9,99 mA |
Dimensions (L x W x H) (mm): | 200 x 150 x 77 |
EN 50678 (prepared): | No |
EN 50699 (prepared): | No |
Earth conductor 10A: | No |
Earth conductor 25A: | No |
High voltage test DC: | No |
Interfaces: | USB |
Isolation: | 0 - 9,99 MΩ |
Measured value memory: | 2000 |
Mobile: | Yes |
Model: | Minitest MASTER |
Protective earth less than 200mA: | Yes |
Software included: | ETC |
Stationary: | No |
Touch Display: | No |
Weight (kg): | 1.5 |
Documents & Downloads
Description
M712U | Minitest MASTER device tester VDE 0701-0702 test device, LCD display, memory
The test device is intended for testing and measuring repaired or modified devices. For this purpose, the test object is connected to the test device via the test socket.
To test the protective conductor current and the contact current (absence of voltage from touchable conductive parts), the device under test is connected to the mains socket of the test device. Limit violations are optically signaled by nine differently colored LEDs. In addition, all measured values are displayed on a large, two-line digital display so that they are easy to read. The handy device has a compact plastic housing with a permanently connected power cord. The respective measured variable is selected with the rotary switch.Checking the electrical safety of electrical equipment: according to DIN VDE 0701-0702: 2008 by measuring protective conductor resistance, insulation resistance, protective conductor current - method residual current, contact current - method direct measurement and absence of voltage by current measurement.
Accessoires (3 products )
Alternate products (11 products )
Recommendations (16 products )
News and Knowledge
The DIN VDE regulations govern the electrotechnical regulations as defined by DGUV V3 (accident prevention regulations f...
Thomas Schleich is an engineer, an expounder of ideas, a free spirit – and a first-class speaker at the dataTec Academy....