Manufacturer number: M535K
All-current sensitive RCDs type B, B+: | Yes |
---|---|
Article number: | M535K |
Automatic test sequence: | Yes |
Check residual voltage: | Yes |
Counter start-up: | Yes |
DIN VDE 0100 / IEC 60364-6: | Yes |
Dimensions (L x W x H) (mm): | 260 x 330 x 90 |
Insulation measurement 50V: | Yes |
Insulation measurement 100V: | Yes |
Insulation measurement 250V: | Yes |
Insulation measurement 325V: | Yes |
Insulation measurement 500V: | Yes |
Insulation measurement 1000V: | Yes |
Interfaces: | USB |
Measured value memory: | 50000 |
Mobile: | Yes |
Model: | Profitest MFTECH |
Rotating field direction: | Yes |
Selective, SRCDs, PRCDs, type G/R: | Yes |
Software included: | Izytroniq |
Stationary: | No |
Touch Display: | No |
Voltage drop: | Yes |
Warranty (years): | 10 |
Weight (kg): | 2.7 |
e-Mobility (prepared): | Yes |
The Gossen Metrawatt M535K PROFITEST MFTECH supports you in testing the effectiveness of protective measures on stationary electrical installations. You can use both programmable and predefined test sequences that comply with test standards such as VDE100-600 or EN 50110-1.
Due to the high memory concept and the programmability, the test device is extremely user-friendly. A wide-range measuring device enables the test device to be used for all AC and three-phase networks with voltages from 65 to 500 V and frequencies from 15.4 to 420 Hz.
Protective measures in electrical systems are intended to protect human life from accidents involving electricity and thus ensure its integrity. Of course, they should also protect material values from damage caused by electricity. Every electrical installation must be tested with this VDE test device before it is put into operation for the first time and then at regular intervals for the effectiveness of the existing electrical protective measures. Your advantage: low-impedance, insulation, earth resistance, site insulation, loop and network impedance measurement and legally compliant documentation in one test device.
The DIN VDE regulations govern the electrotechnical regulations as defined by DGUV V3 (accident prevention regulations f...