Gossen Metrawatt M712D | Minitest PRO device tester VDE 0701-0702 test device, LCD display
Manufacturer number: M712D
Gossen Metrawatt M712D | MINITEST Pro - test device for DIN VDE 0701/0702.
- Limit violations are indicated by LEDs
- Probe line protected by fuse
- Digital display for measured values
- USB interface for data logging (test device must be permanently connected to the PC)
- RCCB installed
- Comprehensive security facilities
- incl. MINITEST MASTER software for reading and printing the measured values
Technical Data
Article number: | M712D |
---|---|
Automatic test sequence: | No |
DIN VDE0544-4 / IEC 60974-4: | No |
DIN VDE 0701-0702: | Yes |
DIN VDE 0751 / IEC62353: | No |
Differential power: | 0,1 - 9,99 mA |
Dimensions (L x W x H) (mm): | 200 x 150 x 77 |
EN 50678 (prepared): | No |
EN 50699 (prepared): | No |
Earth conductor 10A: | No |
Earth conductor 25A: | No |
High voltage test DC: | No |
Interfaces: | USB |
Isolation: | 0 - 9,99 MΩ |
Measured value memory: | No |
Mobile: | Yes |
Model: | Minitest PRO |
Protective earth less than 200mA: | Yes |
Software included: | ETC |
Stationary: | No |
Touch Display: | No |
Weight (kg): | 1.5 |
Documents & Downloads
Description
M712D | Minitest PRO device tester VDE 0701-0702 test device, LCD display
The test device is intended for testing and measuring repaired or modified devices. For this purpose, the test object is connected to the test device via the test socket.
To test the protective conductor current and the contact current (absence of voltage from touchable conductive parts), the device under test is connected to the mains socket of the test device. Limit violations are optically signaled by nine differently colored LEDs. In addition, all measured values are displayed on a large, two-line digital display so that they are easy to read. The handy device has a compact plastic housing with a permanently connected power cord. The respective measured variable is selected with the rotary switch.
Checking the electrical safety of electrical equipment: according to DIN VDE 0701-0702: 2008 by measuring protective conductor resistance, insulation resistance, protective conductor current - method residual current, contact current - method direct measurement and absence of voltage by current measurement.
Accessoires (2 products )
Alternate products (11 products )