Teledyne FLIR E76 | Thermal imaging camera 320x240px 24° + 42° optics, MSX, autofocus, Thermal Studio reporting software (78515-1101)
Manufacturer number: 78515-1101
Teledyne FLIR 78515-1101 | E76 thermal imaging camera Exx series, with 307,200 UltraMax temperature measuring points (320 x 240 px), 24 ° & 42 ° lens (exchangeable), MSX technology, -20 ° C to + 650 ° C (optionally up to 1,000 ° C), thermal sensitivity < 30 mK.
- Display: 640 x 480 px touchscreen
- IR resolution: 320 x 240 px
- UltraMax: 307,200 px
- MSX: Yeah
- Built-in digital camera: 5 MP including built-in LED light
- Temperature range: -20 ° C - 120 ° C || 0 ° C - 650 ° C
- Accuracy: ± 2 ° C / ± 2%
- Focus: Continuous Laser Distance Meter (LDM), one-shot LDM, one-shot contrast, manual
- Digital zoom: 1 - 4 continuously
- Lens: 24 ° & 42 ° | optionally available 14 °, macro (2x)
- Integrated report builder: voice annotations and GPS markings, on-screen text, drawing function directly on the thermal image
- Software integration: Flir Thermal Studio || Flir Research Studio
- Connections: USB, Bluetooth, Wi-Fi, DisplayPort
- Meter link: Yes
- Max. Battery runtime:> 2.5 h
Technical Data
Article number: | 78515-1101 |
---|---|
Model: | E76 24°+24° |
Resolution in pixels: | 320 x 240 |
Temperature measuring points: | 76800 |
Thermal sensitivity (mK): | 40 |
Documents & Downloads
Description
E76 | Thermal imaging camera 320x240px 24° + 42° optics, MSX, autofocus, Thermal Studio reporting software (78515-1101)
The Flir thermal imaging camera E76 of the EXX series helps to quickly uncover thermal problems in electrical and electronic systems, to determine mechanical faults and to carry out preventive maintenance measures.
The object is examined holistically pixel by pixel (each pixel with its own temperature information) and delivers the diagnosis results immediately. The fully equipped one-hand infrared camera with built-in digital camera combines an infrared and real image with the MSX picture-in-picture function : a daylight image is simultaneously superimposed by the radiometric infrared image. In this way, critical problems can be identified even faster and more precisely.
The measurements / thermographic images are saved as JPG, with fully radiometric measurement data per pixel.
The FLIR E76 supports FLIR Inspection Route and enables the integration of the FLIR Thermal Studio and FLIR Research Studio software . FLIR Inspection Routes guides the user along a pre-defined route of inspection points so that they can collect images and data in a structured manner.