Chroma 63600-2 | Electronic load mainframe 2-slot for 2 load modules 636xx series, USB
Manufacturer number: 63600-2
Chroma 63600-2 | 2-slot mainframe for programmable DC replacement loads.
- Mainframe, 2 slot width
- Max. Output with modules: 100 W x 2 (dual), 300 W & 400 W
- Voltage range: up to 600 V
- Up to 10 channels in one mainframe suitable for testing multiple SMPS outputs
- 0.4 V at 80 A (typical) operating characteristic at low voltage
- Flexible CC, CR, CV and CP modes of operation
- CZ (Constant Impedance) mode for capacitive load simulation when switching on
- Parallel mode for high-current and high-performance applications up to 2 kW
- Synchronous multi-channel control
- Automatic frequency swing up to 50 kHz
- Transient reaction simulation of the power supply load in real time and measurement of Vpk +/-
- User-programmable 100 processes for front panel input status for user-friendly operation
- Precise voltage and current measurement
- Precise digitization measurement / data acquisition at high speed
- Measurement of voltage, current and Pmax for OCP / OLP testing
- Timing measurement for batteries
- Short circuit simulation
- Self-test when switching on
- Comprehensive protection: OC, OP, OT protection and OV alarm
- USB interface
- Dimensions: Height: 177 mm x width: 210 mm x depth: 554 mm
- Empty weight: 11.5 kg
- 2 year guarantee
Technical Data
DC output reversible: | DC sink |
---|
Documents & Downloads
Description
63600-2 | Electronic load mainframe 2-slot for 2 load modules 636xx series, USB
The loads are designed for testing power supplies, DC / DC converters, chargers, batteries, adapters and high-performance electronic components. They are ideal for research, development, production and incoming goods inspections. They use DSP technology to simulate non-linear loads with a CZ (constant impedance) operating mode, so that realistic load behavior can be represented.
The series can draw its nominal current at a very low voltage. This special function guarantees optimal load performance for modern point-of-load conditions and fuel cells. Real-time measurements of voltage and current are integrated in each module with a 16-bit precision measuring circuit with three current ranges.