Chroma 63205A-600-350 | DC load, 5 kW, 600 V / 350 A, programmable
Manufacturer number: 63205A-600-350
On Request
Chroma 63205A-600-350 | Electronic load for high power, 600 V, 350 A, 5 kW, 19 inches, 4 U.
- Maximum input power: 5,000 W
- Voltage range: 600 V DC
- Current range: 350 A (maximum)
- Control mode: constant current, resistance, voltage, (CC, CR, CV)
- Complex control mode: CR + CC, CR + CV, CC + CV
- Parallel connection of up to 20 devices in master / slave mode
- Dynamic-synchronous control with static as well as dynamic loads
- Application-specific (arbitrary) load change (UDW / User Defined Waveform)
- CZ (Constant Impedance / Constant Impedance) mode for simulating capacitive loads in switch-on mode
- External current-load simulation
- Automatic sweep / or load changes with a frequency up to 50 kHz
- Power supply load transient simulation in real time and peak value measurements (Vpp + / Vpp-) -
- 256 user-specific device settings that can be called up
- Very accurate voltage and current measurements
- Interfaces: USB (standard), Optional: Ethernet, GPIB
- Dimensions: Height: 176 mm, width: 428 mm, depth: 647 mm
- Weight: 35 kg
- Warranty: 2 years
Technical Data
AC input: | 100 V - 240 V |
---|---|
Article number: | 63205A-600-350 |
DC output reversible: | DC sink |
Dimensions (L x W x H) (mm): | 647 x 428 x 177 |
Interfaces: | USB optional: GPIB |
Mains feedback: | No |
Measurement functions: | V, I, Wmax OCP/OLP |
Model: | 63205A-600-350 |
Output power (kW): | 5 |
Protective devices: | OCP, OPP, OTP, OVA, Reverse |
Weight (kg): | 35 |
max. Power (A): | 350 |
max. Voltage (V): | 600 |
Documents & Downloads
Description
63205A-600-350 | DC load, 5 kW, 600 V / 350 A, programmable
The Chroma 63200A series are programmable, high performance electronic loads with very fast load control mechanisms. The high power density not only saves space, the high measurement accuracy for voltage (0.015% + 0.015% FS) and current (0.04% + 0.04% FS) ensures the reliability of measurement results. The devices in this series can be controlled either manually or by PC. In order to process higher outputs, several devices of the same type can be connected in parallel using a master / slave technology. These electronic loads have synchronized load distribution in order to simulate application-specific variable load situations.
These electronic loads are predestined for testing server power supplies, A / D power supplies, batteries / rechargeable batteries and for energy storage systems, EV / EVSE (Electronic Vehicle / Electronic Vehicle Supply Equipment // Electric vehicles / Electric vehicle power equipment) , Solar power elements and other power electronics.