Chroma 63102A | Electronic load module for mainframes 631xA, 80V / 20A, 2x100W, 2-channel
Manufacturer number: 63102A
or choose one of the following options:
Chroma 63102A | Electronic DC load module, 2 channels, 100 W each, 2 ranges per channel: 0 to 2 A and 0 to 20 A at max. 80V for the mainframes 6312A and 6314A.
- Two channels: input power 100 W each
- Two areas per channel:
0 to 2 A, resolution 0.5 mA
0 to 20 A, resolution 5 mA - Max. Voltage in constant voltage mode: 80 V
- Synchronization with multiple load modules
- Can be connected in parallel in master-slave mode
- Constant voltage (CV), current (CC), resistance (CR), power (CP)
- Dynamic loads with frequencies up to 20 kHz
- Flexible load simulation change from 0.32 mA / µs to 10 A / µs z. B. for the automotive and semiconductor industries
- Minimal input resistance allows load conditions at high currents and low load voltages
- Real-time transients enable simulation of a power supply load and associated measurement of the output values
- User-specific programming over 100 sequences
- Test for limit values (mask) for go / no-go selection
- Digital I / O for module control
- Overcurrent protection (OCP) test function
- Dimensions: Height: 172 mm x width: 82 mm x depth: 489.5 mm
- Slot width: 1 slot
- Weight: 4.2 kg
- Warranty: 2 years
Technical Data
AC input: | 115 V - 230 V |
---|---|
Article number: | 63102A |
DC output reversible: | DC sink |
Dimensions (L x W x H) (mm): | 489,5 x 82 x 172 |
Interfaces: | RS232C optional: USB, GPIB |
Mains feedback: | No |
Measurement functions: | 16-bit dual range I & V |
Model: | 63102A |
Protective devices: | OPP, OCP, OTP, OVA |
Weight (kg): | 4.2 |
max. Power (A): | 20 |
max. Voltage (V): | 80 |
Documents & Downloads
Description
63102A | Electronic load module for mainframes 631xA, 80V / 20A, 2x100W, 2-channel
The Chroma 63102A load module is a slot for the 6312A or 6314A mainframes and offers two independent load channels. Each of these channels has 2 ranges: First a load current range 0 to 2 A and one with 0 to 20 A. The maximum input voltage can be 80 V for all channels and in all ranges. In the smaller areas the minimum load resolution is 0.5 mA, in the larger area the resolution is 5 mA.
News and Knowledge
Applications
With the increasing importance of renewable energies in the wake of climate change, solar energy is moving further into ...
81b71f0fd49f4615b08e888b65008eb8
81b71f0fd49f4615b08e888b65008eb824fd2c72ff294efab3172e881a35fffe
Reading time 5 Min.
645
2
Future & Trends
Power supply units are as diverse as their areas of application. What do you personally use your power supply unit for? ...
0f0b6b6a014f4b4abad8853dd22648fc
0f0b6b6a014f4b4abad8853dd22648fc24fd2c72ff294efab3172e881a35fffe
Reading time 5 Min.
288
0
About the Manufacturer
Chroma
Chroma ATE is the world's largest supplier of power test instruments and
systems, including programmable AC sources and DC power supplies,
laboratory power supplies, AC and DC electronic loads, digital meters,