Chroma 61511 | AC source, 12 kVA, 300 V, 15 to 1.5 kHz, integr. PLD simulation, network simulator
Manufacturer number: 61511
Chroma 61511 | Programmable 1- / 3-phase AC source 3-phase 300 V / 96 A, 12,000 VA, 15-1500 Hz with DC output mode and with harmonics generator and mains interference simulation.
- Output: selectable one or 3 phases, DC or AC
- Output AC, one phase: 12,000 VA, 0 - 300 V / 0 - 150 V, 96 A / 48 A, 15-1500 Hz,
- AC output, three phases: 4000 VA, 0 - 300 V / 0 - 150 V, 16 A / 32 A each
- Output DC, one phase; 6000 W, 212 V / 424V, 48 A / 24 A.
- DC output, 3 phases; 2000 W each, 212 V / 424 V /, 16 A / 8 A
- Integrated power factor correction with input power factor above 0.98 (full load)
- AC + DC output mode for simulation of a DC offset
- Programmable voltage and current limit
- Comprehensive measuring capacity, V, Hz, Irms, Ipk, Iinrush, P, VAR, VA, PF, CF of the current etc.
- High output current crest factor, ideal for testing the inrush current
- Phase control when switching on and off
- Call up 9 different voltages and frequencies with one button
- TTL signal that shows the steady state of the output values after a change
- Programmable current rise rate setting to change voltage and frequency
- Analog input for power amplification
- Analog programming interface as an option
- Comprehensive protection: OP, OC, OV and OT protection
- Convenient PC software soft panel (GUI) for easy control and regulation included
- Can provide an output power of up to 90 KVA by implementing a master-slave operation
- Interfaces: GPIB, RS-232, USB and Ethernet
- Dimensions: width: 546 mm x height: 1163 mm x depth: 700 mm
- Weight: 229.4 kg
- 2 year guarantee
Technical Data
AC input: | 3P |
---|---|
AC output: | 1P / 3P |
Article number: | 61511 |
DC output reversible: | AC Source |
Dimensions (L x W x H) (mm): | 700 x 546 x 1163 |
Frequency range: | 15 Hz - 1,5 kHz |
Grid simulation: | No |
Interfaces: | USB, LAN, GPIB, RS-232 |
Mains feedback: | No |
Measurement functions: | V, Hz, Irms, Ipk, Iinrush, P, VAR, VA, PF, CF of current |
Model: | 61511 |
Output power (kW): | 4 |
PLD Testfunction: | Yes |
Protective devices: | UVP, OCP, OPP, OTP, FAN |
Weight (kg): | 229.4 |
max. Power (A): | 96 |
max. Voltage (V): | 300 |
Documents & Downloads
Description
61511 | AC source, 12 kVA, 300 V, 15 to 1.5 kHz, integr. PLD simulation, network simulator
These 61500 series AC power sources have a (master-slave) parallel operation function that allows users to expand the AC source power output by connecting AC sources in parallel. The maximum permissible number of AC power sources that can be used for parallel operation is 5 device units.
Therefore, users are able to achieve an output power of up to 90 kVA by combining 5 device units with grouped 18 kVA AC sources in (master-slave) parallel mode. Users can also use the optional A615103 power level as an alternative low-cost solution for parallel operation by using it as a slave device unit.
Lieferumfang
Accessoires (11 products )
Alternate products (10 products )
Recommendations (4 products )
News and Knowledge
With the increasing importance of renewable energies in the wake of climate change, solar energy is moving further into ...
Power supply units are as diverse as their areas of application. What do you personally use your power supply unit for? ...