Chauvin Arnoux P01120050A | D31N current probe, 4 mm, 1800 A 30 Hz - 1.5 kHz, I-Out

Manufacturer number: P01120050A

Clamp current transformer Chauvin-Arnoux D31N for AC current measurement from 1 to 1800A.

  • Enclosure diameter 64 x 150 mm
  • Measuring range: 1 ... 600 A / 1 ... 1200 A / 1 .. 1800 A AC
  • Frequency range: 30 Hz ... 1.5 kHz
  • AC current output - ratio: 500: 1, 1000: 1, 1500: 1
  • Connection on the pliers with 4 mm safety sockets
  • Output with surge protection
  • Suitable for multimeters, oscilloscopes, recorders etc.
  • IEC 1010.2.032, Cat.III, 600 V for industrial applications

Documents & Downloads

Description

P01120050A | D31N current probe, 4 mm, 1800 A 30 Hz - 1.5 kHz, I-Out

Clamp current transformer Chauvin-Arnoux D31N for AC current measurement from 1 to 1800A.