Benning 044106 | IT 200 TRUE RMS installation tester VDE 0100
Manufacturer number: 044106
Benning 044106 | IT 200 TRUE RMS Auto Sequence installation tester VDE 0100
- Display: 4.5 “capacitive color touchscreen
- Low resistance test (± 200 mA) / continuity (7 mA): 0.01 Ω - 2000 Ω
- Insulation resistance (50/100/250/500/1000 V): 10 kΩ - 1000 MΩ
- Line impedance (LINE) / voltage drop (ΔU): 0.01 kΩ - 10 kΩ / 0.1% - 100%
- Loop impedance (LOOP): 0.01 kΩ - 10 kΩ
- Short circuit current (Ipsc): 0.01 A - 200 kA
- FI test (RCD): AC / A / F / B / B + / EV-RCD / MI-RCD / EV-RCM
- Earthing resistance (3-wire and 2-clamp method): Yes via 044113 and 044166, 044167
- Voltage (TRUE RMS) / frequency / rotating field: 1 V - 550 V / 14 Hz - 500 Hz / •
- Current (TRUE RMS): 0.1 mA - 300 A AC / DC via 044038, 0.1 mA - 20 A AC via 044166, 044167
- Power (P, S, Q) / harmonics (THD): 0.01 W - 100 kW via 044038, 044166, 044167
- Illuminance: 0.01 lux - 20 klux via 044111
- Measured value memory: SD card (8 GB)
- Interfaces: USB, RS 232, radio interface (cordless link)
Technical Data
All-current sensitive RCDs type B, B+: | Yes |
---|---|
Article number: | 044106 |
Automatic test sequence: | Yes |
Check residual voltage: | No |
Counter start-up: | No |
DIN VDE 0100 / IEC 60364-6: | Yes |
Dimensions (L x W x H) (mm): | 115 x 230 x 103 |
Insulation measurement 50V: | Yes |
Insulation measurement 100V: | Yes |
Insulation measurement 250V: | Yes |
Insulation measurement 325V: | No |
Insulation measurement 500V: | Yes |
Insulation measurement 1000V: | Yes |
Interfaces: | RS-232, USB |
Measured value memory: | No |
Mobile: | Yes |
Model: | Benning IT 200 |
Rotating field direction: | Yes |
Selective, SRCDs, PRCDs, type G/R: | Selective, SRCDs, PRCD |
Software included: | PC-Win IT 130-200 |
Stationary: | No |
Touch Display: | Yes |
Voltage drop: | Yes |
Weight (kg): | 1.5 |
e-Mobility (prepared): | Yes |
Documents & Downloads
Description
044106 | IT 200 TRUE RMS installation tester VDE 0100
The VDE 0100 TRMS installation tester Benning IT 200 is an Auto Sequence installation tester for standard-compliant testing and documentation of electrical systems and EV charging stations (wall boxes) in charging mode 3.
You can operate the IT 200 easily and intuitively using the 4.5 “color touchscreen and pushbuttons. The order manager supports you in the processing and administration of test orders. Create multi-layered system structures including the planned measurements directly at the location of the test and on the PC.
For testing EV charging stations (EVSE Mode 3), the installation tester has specially adapted auto sequences for 1- and 3-phase wallboxes including functional testing / testing of the charging process using the optional BENNING EV 3-2 measuring adapter
The scope of delivery includes a download link for the BENNING PC-Win IT 130-200 protocol software. The software supports you in the professional management and documentation of test orders for initial and repeat tests. You can also use the software to create extensive system structures including the planned measurements (individual tests and auto sequences) and transfer these to your Benning IT 200
Product features:
- Rlow measurement with 200 mA DC test current and autom. Polarity reversal
- PE resistance measurement under mains voltage (3-wire method)
- Insulation resistance with test voltage of 50 V - 1000 V DC
- Riso all, autotest between all conductors (LN, L-PE and N-PE)
- Riso pre-test, protects connected devices from test damage
- Loop (LOOP) and line impedance (LINE) with 20 A test current including short-circuit current / voltage drop calculation for precise measurement results
- RCD testing with RCD auto, RCD t, RCD I and Uc measurement
- Methods for earth resistance measurement (option): Earthing set and current clamp adapter BENNING CC 4-1 / CC 4-2
- TRMS current, power and harmonic wave measurement (THD) via optional current clamp adapter BENNING CC 4-1 / CC 4-2
- TRMS voltage and frequency measurement, rotating field and varistor test
Features:
- Individual tests and preprogrammed auto sequence measurements for TN / TT networks and EV charging stations (wall boxes)
- Automatic tests at the touch of a button
- Z Auto (U, Zln, Zlpe, Ipsc, Uc) and RCD Auto (RCD t, RCD I, Uc)
- Auto TN rcd (U, Zln, Zlpe, Rpe, ΔU), Auto-TN, -TT and Auto-IT
- Testing of various RCD types: general, selective, AC, A, F, B, B +, EV RCD, EV RCM (RDC-DD), MI RCD and PRCDs
- First fault leakage current in the IT network (isfl)
- Illuminance measurement via BENNING Luxmeter type B (option)
- Voltage monitor for online monitoring of the test connections
- Powerful 4400 mAh Li-ion battery pack for long operating times (optionally expandable to 8800 mAh)
- Large measurement memory on 8 GB SD card
- USB, RS 232 and radio interface (cordless link) for data transmission
- Free firmware updates via PC software
- Delivery including calibration certificate
Lieferumfang
- Benning IT 200 test device
- Padded carrying bag
- Commander test plug
- universal 3-wire test lead
- Probe / alligator clip set
- Shoulder strap
- rechargeable Li-ion battery pack (4400 mAh)
- charger
- USB interface cable
- 8 GB SD card
- Protocol software BENNING PC-Win IT 130-200 via download link
- Calibration certificate