NI/NH Research 863076-01 | 9200-4904-12-480-IVI0 - Battery Test System 1 Channel 40 V, 600 A, 8 kW Source, 12 kW Sink, 480 VAC Input, IVI Driver

Manufacturer number: 863076-01

NH Research 863076-01 | 9200-4904-12-480-IVI0 - Regenerative Battery Test System, 1 Channel, 40V, 600A, 8KW Source, 12KW Load, 480VAC Input, IVI Driver, for EV, Solar PV, Aerospace , energy storage, etc

Manufacturer-independent

Wide variety of brands from dataTec.

To the brands

Large product portfolio

All the highlights of dataTec Switzerland at a glance.

Download here

Demonstration & Consulting

Sales and technical support close to you.

Start request

Technical Data

Documents & Downloads

Description

863076-01 | 9200-4904-12-480-IVI0 - Battery Test System 1 Channel 40 V, 600 A, 8 kW Source, 12 kW Sink, 480 VAC Input, IVI Driver

The NH Research 9200 regenerative battery test system is suitable for industrial laboratory and production testing of modules and packs. It offers expandable power ranges from 12 kW modules up to 252 kW with bidirectional 40V (models 9200-4904) or 120V (models 9200-4912) bidirectional DC loads. Thanks to the uncomplicated expandability, the performance level can be expanded if required. The NHR 9200 meets the ever-evolving battery testing requirements for electric vehicles, renewable energy storage, and critical energy applications.

The 9200 Battery Pack Test System is ideal for applications that require maximum flexibility in configuring battery test systems. Key differentiators from other battery cyclers on the market include flexible control options, modular and scalable performance, fast transients, built-in security, and ease of use.

All NHR battery test systems can be easily integrated into existing test platforms or as a performance stage for new test platforms. To achieve this, NHR provides fully documented drivers using either IVI or SCPO languages along with examples, applications and integration support.

Product features of the MHR 9200 series:

  • R&D and production laboratory testing of battery modules and packs
  • Bidirectional DC source and load
  • High configuration flexibility
  • Modular and scalable power - 12 kW to 252 kW at 40 V or 120 V
  • Regenerative performance > 90% energy efficiency
  • Current, voltage and mode transitions <1 ms
  • Built-in digital measurements with graph and scope displays
  • Battery emulation mode
  • Touch panel, LabVIEW and IVI drivers
  • Enerchron Test Executive

Typical applications:

Battery test:

  • EV/ESS battery module/pack test
  • Start test - stop
  • battery characterization
  • cycling, life cycle
  • loading, unloading
  • Fuel cell test module, stack

Battery emulation:

  • EV powertrain, avionics propulsion systems
  • DC charger
  • Power conversion: DC/DC converter, inverter
  • On-board charger, UPS, Power Distribution Unit (PDU)
  • Microgrid, ESS, PV emulation

Alternate products (23 products)

863075-01
NI/NH Research
863075-01
9200-4904-12-416-IVI0 - Battery Test System 1 Channel 40 V, 600 A, 8 kW Source, 12 kW Sink, 416 VAC Input, IVI Driver
Delivery time upon request
On Request
863075-02
NI/NH Research
863075-02
9200-4904-12-416-SCPI0 - Battery test system 1 channel 40 V, 600 A, 8 kW source, 12 kW sink, 416 VAC input, SCPI driver
Delivery time upon request
On Request
863076-02
NI/NH Research
863076-02
9200-4904-12-480-SCPI0 - Battery test system 1 channel 40 V, 600 A, 8 kW source, 12 kW sink, 480 VAC input, SCPI driver
Delivery time upon request
On Request
863077-01
NI/NH Research
863077-01
9200-4904-24-416-IVI0 - Battery test system 2 channels, each 40 V, 600 A, 8 kW source, 12 kW sink, 416 VAC input, IVI driver
Delivery time upon request
On Request
863077-02
NI/NH Research
863077-02
9200-4904-24-416-SCPI0 - Battery test system 2 channels, each 40 V, 600 A, 8 kW source, 12 kW sink, 416 VAC input, SCPI driver
Delivery time upon request
On Request
863078-01
NI/NH Research
863078-01
9200-4904-24-480-IVI0 - Battery test system 2 channels, each 40 V, 600 A, 8 kW source, 12 kW sink, 480 VAC input, IVI driver
Delivery time upon request
On Request
863078-02
NI/NH Research
863078-02
9200-4904-24-480-SCPI0 - Battery test system 2 channels, each 40 V, 600 A, 8 kW source, 12 kW sink, 480 VAC input, SCPI driver
Delivery time upon request
On Request
863079-01
NI/NH Research
863079-01
9200-4904-36-416-IVI0 - Battery test system 3 channels, each 40 V, 600 A, 8 kW source, 12 kW sink, 416 VAC input, IVI driver
Delivery time upon request
On Request
863079-02
NI/NH Research
863079-02
9200-4904-36-416-SCPI0 - Battery test system 3 channels, each 40 V, 600 A, 8 kW source, 12 kW sink, 416 VAC input, SCPI driver
Delivery time upon request
On Request
863080-01
NI/NH Research
863080-01
9200-4904-36-480-IVI0 - Battery test system 3 channels, each 40 V, 600 A, 8 kW source, 12 kW sink, 480 VAC input, IVI driver
Delivery time upon request
On Request
863080-02
NI/NH Research
863080-02
9200-4904-36-480-SCPI0 - Battery test system 3 channels, each 40 V, 600 A, 8 kW source, 12 kW sink, 480 VAC input, SCPI driver
Delivery time upon request
On Request
863081-01
NI/NH Research
863081-01
9200-4912-12-416-IVI0 - Battery Test System 1 Channel 120 V, 200 A, 8 kW Source, 12 kW Sink, 416 VAC Input, IVI Driver
Delivery time upon request
On Request
863081-02
NI/NH Research
863081-02
9200-4912-12-416-SCPI0 - Battery test system 1 channel 120 V, 200 A, 8 kW source, 12 kW sink, 416 VAC input, SCPI driver
Delivery time upon request
On Request
863082-01
NI/NH Research
863082-01
9200-4912-12-480-IVI0 - Battery Test System 1 Channel 120 V, 200 A, 8 kW Source, 12 kW Sink, 480 VAC Input, IVI Driver
Delivery time upon request
On Request
863082-02
NI/NH Research
863082-02
9200-4912-12-480-SCPI0 - Battery test system 1 channel 120 V, 200 A, 8 kW source, 12 kW sink, 480 VAC input, SCPI driver
Delivery time upon request
On Request
863083-01
NI/NH Research
863083-01
9200-4912-24-416-IVI0 - Battery test system 2 channels, each 120 V, 200 A, 8 kW source, 12 kW sink, 416 VAC input, IVI driver
Delivery time upon request
On Request
863083-02
NI/NH Research
863083-02
9200-4912-24-416-SCPI0 - Battery test system 2 channels, each 120 V, 200 A, 8 kW source, 12 kW sink, 416 VAC input, SCPI driver
Delivery time upon request
On Request
863084-01
NI/NH Research
863084-01
9200-4912-24-480-IVI0 - Battery test system 2 channels, each 120 V, 200 A, 8 kW source, 12 kW sink, 480 VAC input, IVI driver
Delivery time upon request
On Request
863084-02
NI/NH Research
863084-02
9200-4912-24-480-SCPI0 - Battery test system 2 channels, each 120 V, 200 A, 8 kW source, 12 kW sink, 480 VAC input, SCPI driver
Delivery time upon request
On Request
863085-01
NI/NH Research
863085-01
9200-4912-36-416-IVI0 - Battery test system 3 channels, each 120 V, 200 A, 8 kW source, 12 kW sink, 416 VAC input, IVI driver
Delivery time upon request
On Request
863085-02
NI/NH Research
863085-02
9200-4912-36-416-SCPI0 - Battery test system 3 channels, each 120 V, 200 A, 8 kW source, 12 kW sink, 416 VAC input, SCPI driver
Delivery time upon request
On Request
863086-01
NI/NH Research
863086-01
9200-4912-36-480-IVI0 - Battery test system 3 channels, each 120 V, 200 A, 8 kW source, 12 kW sink, 480 VAC input, IVI driver
Delivery time upon request
On Request
863086-02
NI/NH Research
863086-02
9200-4912-36-480-SCPI0 - Battery test system 3 channels, each 120 V, 200 A, 8 kW source, 12 kW sink, 480 VAC input, SCPI driver
Delivery time upon request
On Request

Recommendations (2 products)

863129-01
NI/NH Research
863129-01
Enerchron Test Executive Software, CAN Comm. and Battery Test Controller
Delivery time upon request
On Request
863128-01
NI/NH Research
863128-01
Enerchron Test Executive Software and Battery Test Controller
Delivery time upon request
On Request

About the Manufacturer

NI/NH Research
NI/NH Research
NH Research (NHR) beschleunigt die Elektrifizierung durch innovative Prüf- und Validierungslösungen. Mit über 50 Jahren Erfahrung in Leistungsumwandlung und Elektrifizierungsprüfung bietet NHR erstklassige Instrumente und Systeme für verschiedene Branchen. Die Lösungen von NHR, nun Teil von NI seit der Übernahme im Jahr 2021, bieten Ingenieuren und Forschern die Leistung und Sicherheit, um Testzeiten zu verkürzen und die Energieeffizienz zu maximieren. Gemeinsam mit NI bietet NHR umfassendere Elektrifizierungslösungen, um Testabläufe zu optimieren und die Markteinführungszeiten zu verkürzen.

Last Seen Products

Product added to compare
Product Compare added Product Compare