The PEL 100 performance data loggers from Chauvin Arnoux impress with their robustness, numerous networking options, constant data recording, standard-compliant measurements and numerous voltage and current inputs.
The PEL106 is no exception. The device measures and stores all relevant data for precise measurement of energy consumption - you can use the PEL106 without interrupting the power supply.
When it comes to the compactness of the energy meter, there is no way around the PEL106. As a handy and transportable device, the PEL106 can be easily installed. The 4 voltage inputs and the 4 current inputs give you enough options to connect the device.
The power supply is secured via the supplied accessory - batteries and rechargeable batteries are therefore obsolete. The illuminated LC display shows you three measured values digitally - thanks to the brightness, you can easily and reliably read the measured values even in dark surroundings and at night.
The SD memory card allows you to save measurement data over a period of several years.
The PEL106 is suitable for all network types and automatically detects the connected sensors.
Measurements can be made with the PEL106 without any problems. The PEL106 has an alarm mode: You as the user can set alarm thresholds for measured values, a list of alarm events is then automatically created and, if necessary, you will automatically receive an e-mail should such an event occur.
Key facts about measurements with the PEL106
- Voltages up to 1000 V AC / V DC
- Currents up to 10 kA AC / 5 kA DC
- Services up to 10 GW / Gvar / GVA
- Energies up to 4 EWh / EVAh / Evarh
The greatest strength of the PEL106 is its connectivity. Communication options include USB, Ethernet, Bluetooth, Wifi and 3G / GPRS. At the same time, the function of the PEL106 can be controlled and adjusted using an Android app. With the "PEL Transfer" software, Chauvin Arnoux offers the possibility of evaluating the stored data.
Technical data of the PEL106
- Display: four-line digital display
- Plant types: single-phase, two-phase, three-phase and others.
- Number of measurement inputs: 3 voltage inputs, 3 current inputs
- Mains frequencies: DC, 50 Hz, 60 Hz and 400 Hz
- Voltage: 10 - 10000 V AC / V DC
- Current: from 5 mA AC to 10 kA AC / 50 mA DC to 1.4 kA DC
- Measurements: 5 measurements per second
- Storage: 8 GB SD card
- Communication: Ethernet, Bluetooth, USB, WiFi and GPAS
- Dimensions 245 x 270 x 180 mm
- Weight: <3400 g
- Housing protection class IP67
Further technical data can be found in the attached data sheet.