The PXI ‑ 6224 offers analog inputs, synchronized digital I / O, two counters / timers with 32 bit resolution and digital triggering. The module includes inexpensive, reliable data acquisition capabilities for a wide range of applications, including simple applications in laboratory automation, research and development, design validation / review, and production testing. Functions for measuring sensors and high voltages can be added to the module via SCC or SCXI signal conditioning modules. The NI ‑ DAQmx driver with configuration program included in the scope of delivery simplifies the configuration and the execution of measurements.
Product features:
- Bus type: PXI Hybrid
- Maximum number of ground-related analog input channels: 32
- Maximum number of differential analog input channels: 16
- Simultaneous sampling: No.
- Maximum sampling rate: 250 kS / s
- Resolution analog input: 16 bit
- Absolute accuracy of analog input: 3100 μV
- Number of analog output channels: 0
- Maximum update rate: -
- Number of bidirectional digital channels: 48
- Direction of current flow: -
- Number of counters / timers: 2
- Measured electrical signal: voltage
- Analog input FIFO buffer size: 4095 samples