Chauvin Arnoux P01120050A | D31N current probe, 4 mm, 1800 A 30 Hz - 1.5 kHz, I-Out

Manufacturer number: P01120050A

Clamp current transformer Chauvin-Arnoux D31N for AC current measurement from 1 to 1800A.

  • Enclosure diameter 64 x 150 mm
  • Measuring range: 1 ... 600 A / 1 ... 1200 A / 1 .. 1800 A AC
  • Frequency range: 30 Hz ... 1.5 kHz
  • AC current output - ratio: 500: 1, 1000: 1, 1500: 1
  • Connection on the pliers with 4 mm safety sockets
  • Output with surge protection
  • Suitable for multimeters, oscilloscopes, recorders etc.
  • IEC 1010.2.032, Cat.III, 600 V for industrial applications

Independant Consulting

More than 25 strong brands and exclusive partnerships.

About the brands

Services

More than instruments: Before, during and after sales.

Go to the services

Demonstration & Consulting

Sales and technical support close to you.

Start request

Documents & Downloads

Description

P01120050A | D31N current probe, 4 mm, 1800 A 30 Hz - 1.5 kHz, I-Out

Clamp current transformer Chauvin-Arnoux D31N for AC current measurement from 1 to 1800A.

Accessoires (3 products )

Accessoires (3 products )

PMK 934-068-101
Touch-proof measuring line, 4mm stackable plug, red, 0.5m
Delivery time upon request
€7.25
PMK 934-068-102
Touch-safe measuring line, 4mm stackable plug, blue, 0.5m
Delivery time upon request
€7.25
PMK 934-095-100
Touch-proof measuring cable, plug 4mm stackable, black, 1m
Delivery time upon request
€8.25

About the Manufacturer

Chauvin Arnoux
Chauvin Arnoux stands for highest quality and innovative, highly reliable test equipment in the fields of electrical safety testing, measurement of electrical quantities, power measurement, energy and fault analysis.

Last Seen Products

Product added to compare
Product Compare added Product Compare